Skip to main content

Security report for kzcr.eu

Krajská zdravotní, a.s. · Healthcare · Czech Republic

High risk. 9 critical or high findings in GDPR outside view, Network security and 2 other checks.

Security score

49/100

Risk levelHigh

0–100, higher is better. How it is calculated

Krajská zdravotní, a.s. is a major healthcare provider operating multiple hospitals and specialized medical services in the Ústecký region of the Czech Republic. The website serves patients, healthcare professionals, and employees with information about services, news, and organizational details. The company holds a strong regional market position as a public healthcare entity. Technically, the website is built on ASP.NET Web Forms with standard web technologies and includes modern features such as Google Tag Manager and cookie consent mechanisms. Security posture is adequate with HTTPS enforced and secure form handling, but lacks advanced security headers and incident response disclosures. Overall, the site is professional, trustworthy, and compliant with basic privacy regulations, though improvements in security transparency and contact information visibility are recommended.

Scanned

NIS2 and GDPR posture

GDPR outside view
10/ 100 · Critical
Checks completed
7of 7

NIS2 Art. 21(2)

  1. (a) Risk analysis and security policies: Not visible from outside
  2. (b) Incident handling: One indicator
  3. (c) Business continuity, backups and crisis management: Not visible from outside
  4. (d) Supply chain security: Not visible from outside
  5. (e) Secure acquisition, development and maintenance, including vulnerability handling: Partly checked
  6. (f) Assessing the effectiveness of security measures: Not visible from outside
  7. (g) Cyber hygiene and security training: Not visible from outside
  8. (h) Cryptography and encryption: Partly checked
  9. (i) HR security, access control and asset management: One indicator
  10. (j) Multi-factor authentication and secured communications: Not visible from outside

This scan rated NIS2 with an earlier keyword method that is no longer shown; rescan for the per-article view. Risk management, continuity, supply chain, training, MFA, management oversight (Art. 20) and incident reporting (Art. 23) need internal evidence, and Guard cannot tell whether NIS2 applies to this organisation.

GDPR is indicative only, based on publicly visible signals: Articles 7, 12, 13 and 32 of Regulation (EU) 2016/679 and Article 5(3) of the ePrivacy Directive. Not a certification or legal assessment.

Priority findings

9 findings rated critical or high. Fix these first.

  1. GDPR outside view

    These are the privacy signals visitors and data protection authorities look for under GDPR.

    • Critical

      EU business without adequate privacy measures

      EU businesses are subject to strict GDPR requirements

      What to do: Implement comprehensive GDPR compliance including privacy policy, cookie consent, and data protection measures

    • High

      No Privacy Policy found

      GDPR requires a clear and accessible privacy policy

      What to do: Add a comprehensive privacy policy page and link to it prominently

    • High

      No Cookie Policy found

      GDPR requires clear information about cookie usage

      What to do: Add a dedicated cookie policy explaining cookie usage and purposes

  2. Network security

    Services reachable from the internet are the first thing attackers probe. Anything open that does not need to be should be closed.

    • Critical

      Critical Service Exposed: MSSQL

      Port 1433 (MSSQL) is publicly accessible - MSSQL - Database server

      What to do: Immediately restrict access to MSSQL using firewall or VPN

      • NIS2 21(2)(e)
      • IR 2024/2690 6.7.2(f): Implementing Regulation (EU) 2024/2690, Annex point 6.7.2(f): Network security
      • NIST CM-7: NIST SP 800-53 Rev. 5 CM-7: Least Functionality
      • NIST SC-7: NIST SP 800-53 Rev. 5 SC-7: Boundary Protection
  3. Security headers

    Security headers are instructions your web server sends to every visitor’s browser. Missing ones leave visitors more exposed to attacks such as clickjacking and injected scripts.

    • High

      Missing Content-Security-Policy header

      Controls resources the browser is allowed to load

      What to do: Implement a Content-Security-Policy appropriate for your application

      • ASVS V3.4.3
      • OWASP Secure Headers: OWASP Secure Headers Project recommends Content-Security-Policy: default-src 'self'; form-action 'self'; base-uri 'self'; object-src 'none';…

Need hands-on remediation? Email guard@offseq.com

Keep watching kzcr.eu

This scan found 24 issues across 6 checks. Monitoring re-runs those checks daily, emails you when something material changes and records each fix, so you can show progress.

Daily monitoring

Recommended

€25per month

  • TLS certificates and expiry
  • DNS records
  • SPF, DKIM and DMARC
  • Security headers
  • GDPR and NIS2 posture
  • Exposed services
  • Third-party trackers
  • Security score drift

Email alerts on material changes and an exportable JSON history of every change.

Billed monthly to your card. Cancel anytime. See sample alerts.

Full report

€39.90one-time

  • The complete analysis as a PDF you can cite
  • Email delivery with an unlock code
  • Lifetime access to this report

Prices incl. 21% VAT. Secure checkout by Mollie; sold by SEQ SIA, Latvia.

Results by check

Each check with its score, findings and the evidence it collected.

How this score is calculated

The security score runs 0–100, higher is better. It is the plain average of the security checks that completed in this scan, each counted equally. A check that could not run is left out: it counts neither as a pass nor as a fail.

Counted in this score

SSL/TLS
77
Security headers
45
Email security
80
DNS health
85
Network security
0
GDPR outside view
10
Average
50
After the cap
49

Not counted

  • NIS2 outside view: Re-weights evidence from the TLS, email, DNS, network and hygiene checks, so counting it would count that evidence twice. Shown on its own.
  • OffSeq Observations: An AI reading of the site, useful context but not reproducible evidence. Shown on its own.

Findings that cap the score at 49

Each of these is serious on its own, so while any is present the site cannot rate better than high risk, however good the other checks are.

  • The certificate is not trusted by browsers
  • The website is not served over HTTPS
  • A database, remote desktop, file-sharing or Telnet service is reachable from the internet · found on this site
  • The page loads a script from a compromised source
  • The domain registration has expired
  • SPF authorises every server to send mail as the domain

Partial scans

When the site blocks Guard or most checks cannot run, the score covers only the checks that ran (usually DNS and email), is capped at 75 and is shown as partial, without a risk level.

Risk levels

  • Critical0–25
  • High26–49
  • Medium50–75
  • Low76–100

Technical appendix

Business context, site observations and technical notes gathered during the scan, and the standards behind each reference.

Business context

Business profile

The company operates in the healthcare sector, focusing on hospital and specialized medical care. Its business model is public healthcare provision with a large operational scale in the Czech Republic. The website reflects a mature digital presence with clear navigation and relevant content for its audience. Partnerships with regional government entities are evident. The organization emphasizes patient care, employee services, and medical education. No direct revenue streams or commercial activities are visible on the site, consistent with a public healthcare provider. Growth indicators include expansion of medical services and new facilities. The partnership ecosystem includes regional authorities and social media engagement.

Security posture

The website demonstrates a moderate security maturity level with HTTPS enabled and secure ASP.NET form mechanisms. However, it lacks several recommended HTTP security headers and does not publish an incident response or vulnerability disclosure policy. No exposed sensitive data or vulnerable libraries were detected in the provided content. The use of third-party scripts like Google Tag Manager and Cookie Script introduces some tracking but is standard practice. The absence of explicit security contact channels and certifications suggests room for improvement in security governance and transparency. Compliance with GDPR is indicated by privacy and cookie policies, but more comprehensive security documentation would enhance trust.

Recommendations

  1. Implement HTTP security headers such as Content-Security-Policy, X-Content-Type-Options, X-Frame-Options, and Strict-Transport-Security to improve security posture.
  2. Publish an incident response policy and provide clear security contact information to enhance transparency and readiness.
  3. Introduce a vulnerability disclosure policy or security.txt file to encourage responsible reporting of security issues.
  4. Enhance visibility of contact information including verified company emails and phone numbers on the website for better user trust and support.
  5. Regularly audit and update third-party scripts and dependencies to mitigate potential vulnerabilities.
Site observations

Automated reading of the public site. Ratings are indicative.

Business

Company
Krajská zdravotní, a.s.
Description
Krajská zdravotní, a.s. is a healthcare provider operating multiple hospitals and medical facilities in the Ústecký region of the Czech Republic. It offers a wide range of medical services including cardiology, psychiatry, pediatric palliative care, vaccination centers, and more.
Key services
Hospital care, Specialized medical clinics, Vaccination centers, Patient information and support, Employee services, Medical education and research
Content quality
good
Branding
consistent

Technology

Stack
ASP.NET Web Forms, jQuery, Google Fonts, Google Tag Manager, Cookie Script
Frameworks
ASP.NET
Performance
moderate
Mobile
good
Accessibility
basic
SEO
basic

Security

Observed score
75/100
Good practices seen
  • HTTPS enforced
  • Use of secure forms with __VIEWSTATE and __EVENTVALIDATION tokens
  • Cookie consent script implemented

Analytics and tracking

Services
Google Analytics (via Google Tag Manager)
Tracking level
moderate
Privacy practices
basic

Advertising

Marketing tools
Cookie Script
Transparency
basic

Site quality

Design
good
User experience
good
Content relevance
good
Navigation
good
Professionalism
good
Trustworthiness
high

Key observations

  1. Website is fully accessible with no blocking or WAF challenges.
  2. Content is primarily in Czech language targeting regional healthcare consumers and professionals.
  3. No explicit privacy or security policy pages beyond basic privacy and cookie policies.
  4. No visible contact emails or phone numbers directly on homepage; contact info likely on dedicated pages.
  5. Use of ASP.NET Web Forms technology with standard Microsoft web controls.
  6. Social media presence on Facebook, Instagram, and YouTube with official profiles linked.
  7. No visible security.txt or vulnerability disclosure policy.
  8. No explicit incident response or security contact information found.
  9. No visible certifications or compliance badges displayed on site.
  10. Cookie consent implemented via third-party script.
Technical notes

Notes

The website is built on ASP.NET Web Forms technology, indicating a legacy but stable platform. It uses jQuery and Google Fonts for UI enhancements and Google Tag Manager for analytics. The site is mobile responsive with good navigation structure but could improve accessibility features. Performance is moderate, likely due to server-side rendering and multiple scripts. The CMS appears custom-built on ASP.NET, which may limit rapid modernization. Hosting details are not explicit but the domain is registered with a reputable Czech registrar. There is an opportunity to modernize the tech stack and improve SEO and accessibility compliance.
Standards and sources

Reference chips under each finding point to the standard, regulation or specification the finding relates to. They are taken from the official datasets below and mapped conservatively: a finding with no defensible link shows none. NIS2 and GDPR references mark where a finding is relevant evidence, not a compliance verdict. Implementing Regulation (EU) 2024/2690 binds digital infrastructure and digital service providers; for other entities it is the most detailed public reading of the Article 21 measures. WCAG, EN 301 549, European Accessibility Act and Web Accessibility Directive references name the requirement an automated accessibility rule relates to; they are not a conformance verdict.

Retrieved 2026-10-25

Reviews of this site

Share your experience with kzcr.eu. Every review is verified by email and published after moderation.

Overall rating
Select a rating
4000 characters remaining

We’ll email you to confirm your review and keep your details private.

Community rating

No published reviews yet. Be the first to review kzcr.eu.

Feedback on this report

Rate this report, add an optional comment, and tell us if you want a security specialist to follow up.

Overall report quality
Select a rating
2000 characters remaining

We only use your feedback to improve Guard reports. Contact details are never shared.