Skip to main content

Security report for intemann.com

Intemann GmbH · Energy · Austria

Partial score · DNS & email only

34/100

0–100, higher is better. How it is calculated

Intemann GmbH is a medium-sized Austrian company specializing in technical building services across multiple sectors including energy, industrial plants, commercial and residential construction, and hospitality. The company offers comprehensive services such as planning, prefabrication, ventilation technology, and maintenance. Their market position is that of an established regional player with international project reach, supported by a consistent brand presence and certifications. Technically, the website is built on TYPO3 CMS with a modern JavaScript stack but lacks HTTPS, which is a critical security shortfall. The site includes cookie consent mechanisms and clear contact information, supporting GDPR compliance. However, the absence of SSL/TLS and security policies reduces the overall security posture. Strategic improvements in security infrastructure and incident response readiness are recommended to enhance trust and compliance.

Scanned

NIS2 and GDPR posture

Checks completed
5of 7

NIS2 Art. 21(2)

  1. (a) Risk analysis and security policies: Not visible from outside
  2. (b) Incident handling: One indicator
  3. (c) Business continuity, backups and crisis management: Not visible from outside
  4. (d) Supply chain security: Not visible from outside
  5. (e) Secure acquisition, development and maintenance, including vulnerability handling: Partly checked
  6. (f) Assessing the effectiveness of security measures: Not visible from outside
  7. (g) Cyber hygiene and security training: Not visible from outside
  8. (h) Cryptography and encryption: Partly checked
  9. (i) HR security, access control and asset management: One indicator
  10. (j) Multi-factor authentication and secured communications: Not visible from outside

This scan rated NIS2 with an earlier keyword method that is no longer shown; rescan for the per-article view. Risk management, continuity, supply chain, training, MFA, management oversight (Art. 20) and incident reporting (Art. 23) need internal evidence, and Guard cannot tell whether NIS2 applies to this organisation.

GDPR is indicative only, based on publicly visible signals: Articles 7, 12, 13 and 32 of Regulation (EU) 2016/679 and Article 5(3) of the ePrivacy Directive. Not a certification or legal assessment.

Priority findings

5 findings rated critical or high. Fix these first.

  1. SSL/TLS

    TLS encrypts the connection and proves the site is really yours. Weak or expiring certificates trigger browser warnings and put traffic at risk.

    • Critical

      No HTTPS Encryption

      Website does not use HTTPS encryption, making all data transmission vulnerable to interception

      What to do: Implement SSL/TLS certificate and redirect all HTTP traffic to HTTPS

  2. Network security

    Services reachable from the internet are the first thing attackers probe. Anything open that does not need to be should be closed.

    • Critical

      Critical Service Exposed: SMB

      Port 445 (SMB) is publicly accessible - SMB - Windows file sharing, high risk

      What to do: Immediately restrict access to SMB using firewall or VPN

      • NIS2 21(2)(e)
      • IR 2024/2690 6.7.2(f): Implementing Regulation (EU) 2024/2690, Annex point 6.7.2(f): Network security
      • NIST CM-7: NIST SP 800-53 Rev. 5 CM-7: Least Functionality
      • NIST SC-7: NIST SP 800-53 Rev. 5 SC-7: Boundary Protection
    • Critical

      Critical Service Exposed: MySQL

      Port 3306 (MySQL) is publicly accessible - MySQL - Database server

      What to do: Immediately restrict access to MySQL using firewall or VPN

      • NIS2 21(2)(e)
      • IR 2024/2690 6.7.2(f): Implementing Regulation (EU) 2024/2690, Annex point 6.7.2(f): Network security
      • NIST CM-7: NIST SP 800-53 Rev. 5 CM-7: Least Functionality
      • NIST SC-7: NIST SP 800-53 Rev. 5 SC-7: Boundary Protection
    • High

      High-Risk Service Exposed: FTP

      Port 21 (FTP) is publicly accessible - FTP - Often unencrypted file transfer

      What to do: Consider restricting access to FTP or implementing strong authentication

      • NIS2 21(2)(e)
      • IR 2024/2690 6.7.2(f): Implementing Regulation (EU) 2024/2690, Annex point 6.7.2(f): Network security
      • NIST CM-7: NIST SP 800-53 Rev. 5 CM-7: Least Functionality
      • NIST SC-7: NIST SP 800-53 Rev. 5 SC-7: Boundary Protection
    • High

      High-Risk Service Exposed: NetBIOS

      Port 139 (NetBIOS) is publicly accessible - NetBIOS - Windows file sharing

      What to do: Consider restricting access to NetBIOS or implementing strong authentication

      • NIS2 21(2)(e)
      • IR 2024/2690 6.7.2(f): Implementing Regulation (EU) 2024/2690, Annex point 6.7.2(f): Network security
      • NIST CM-7: NIST SP 800-53 Rev. 5 CM-7: Least Functionality
      • NIST SC-7: NIST SP 800-53 Rev. 5 SC-7: Boundary Protection

Need hands-on remediation? Email guard@offseq.com

Keep watching intemann.com

This scan found 9 issues across 4 checks. Monitoring re-runs those checks daily, emails you when something material changes and records each fix, so you can show progress.

Daily monitoring

Recommended

€25per month

  • TLS certificates and expiry
  • DNS records
  • SPF, DKIM and DMARC
  • Security headers
  • GDPR and NIS2 posture
  • Exposed services
  • Third-party trackers
  • Security score drift

Email alerts on material changes and an exportable JSON history of every change.

Billed monthly to your card. Cancel anytime. See sample alerts.

Full report

€39.90one-time

  • The complete analysis as a PDF you can cite
  • Email delivery with an unlock code
  • Lifetime access to this report

Prices incl. 21% VAT. Secure checkout by Mollie; sold by SEQ SIA, Latvia.

Results by check

Each check with its score, findings and the evidence it collected.

How this score is calculated

The security score runs 0–100, higher is better. It is the plain average of the security checks that completed in this scan, each counted equally. A check that could not run is left out: it counts neither as a pass nor as a fail.

Counted in this score

SSL/TLS
0
Email security
50
DNS health
85
Network security
0
Average
34

Not counted

  • Security headers: did not complete in this scan.
  • GDPR outside view: did not complete in this scan.
  • NIS2 outside view: Re-weights evidence from the TLS, email, DNS, network and hygiene checks, so counting it would count that evidence twice. Shown on its own.
  • OffSeq Observations: An AI reading of the site, useful context but not reproducible evidence. Shown on its own.

Findings that cap the score at 49

Each of these is serious on its own, so while any is present the site cannot rate better than high risk, however good the other checks are.

  • The certificate is not trusted by browsers
  • The website is not served over HTTPS
  • A database, remote desktop, file-sharing or Telnet service is reachable from the internet · found on this site
  • The page loads a script from a compromised source
  • The domain registration has expired
  • SPF authorises every server to send mail as the domain

Partial scans

When the site blocks Guard or most checks cannot run, the score covers only the checks that ran (usually DNS and email), is capped at 75 and is shown as partial, without a risk level.

Risk levels

  • Critical0–25
  • High26–49
  • Medium50–75
  • Low76–100

Technical appendix

Business context, site observations and technical notes gathered during the scan, and the standards behind each reference.

Business context

Business profile

The company targets clients in industrial, commercial, hospitality, and residential sectors, providing technical building solutions. Their business model is project and service-based, focusing on planning and execution of building technical systems. The website reflects a professional and consistent brand with good content quality and navigation. Social media presence and certifications add trust signals. The partnership with intemann.ch suggests regional expansion or sister company relations. The employee portal indicates internal digital infrastructure. No direct revenue or financial data is available, but the breadth of services and international projects imply a stable medium-sized enterprise.

Security posture

The website currently lacks HTTPS, exposing users to potential interception risks. Security headers are minimal but include x-content-type-options and x-ua-compatible. No advanced security policies or incident response contacts are published. Cookie consent is implemented, indicating privacy awareness. The absence of TLS protocols and certificate transparency compliance are significant vulnerabilities. No vulnerability disclosure or security.txt files are present, limiting transparency. Overall, the security posture is weak and requires urgent improvements to meet modern standards and regulatory requirements.

Recommendations

  1. Obtain and deploy a valid SSL/TLS certificate to enable HTTPS across the entire site.
  2. Implement HTTP Strict Transport Security (HSTS) with includeSubDomains and preload directives.
  3. Publish a clear security policy and incident response contact information on the website.
  4. Add security headers such as Content-Security-Policy, Referrer-Policy, and X-Frame-Options.
  5. Establish a vulnerability disclosure program or security.txt file to improve transparency and trust.

Contact details published on the site

Addresses
Legal name
Intemann GmbH
Technical notes

Notes

The website uses TYPO3 CMS with a variety of JavaScript libraries including jQuery, Owl Carousel, ScrollMagic, and GSAP for enhanced UI/UX. Hosting is provided via tele.net with DNS configured properly but no DNSSEC or CAA records. Performance metrics are missing or zero, indicating no data or poor measurement. Mobile optimization is basic but functional. SEO is supported by meta tags and alternate hreflang links. The lack of HTTPS and modern TLS protocols is a critical technical deficiency. The site uses chunked transfer encoding and standard Apache server headers. Cookie management is handled by a dedicated TYPO3 extension. Overall, the technical infrastructure is functional but outdated in security and performance monitoring.
Standards and sources

Reference chips under each finding point to the standard, regulation or specification the finding relates to. They are taken from the official datasets below and mapped conservatively: a finding with no defensible link shows none. NIS2 and GDPR references mark where a finding is relevant evidence, not a compliance verdict. Implementing Regulation (EU) 2024/2690 binds digital infrastructure and digital service providers; for other entities it is the most detailed public reading of the Article 21 measures. WCAG, EN 301 549, European Accessibility Act and Web Accessibility Directive references name the requirement an automated accessibility rule relates to; they are not a conformance verdict.

Retrieved 2026-10-25

Reviews of this site

Share your experience with intemann.com. Every review is verified by email and published after moderation.

Overall rating
Select a rating
4000 characters remaining

We’ll email you to confirm your review and keep your details private.

Community rating

No published reviews yet. Be the first to review intemann.com.

Feedback on this report

Rate this report, add an optional comment, and tell us if you want a security specialist to follow up.

Overall report quality
Select a rating
2000 characters remaining

We only use your feedback to improve Guard reports. Contact details are never shared.