Skip to main content

Security report for fnkv.cz

Fakultní nemocnice Královské Vinohrady · Healthcare · Czech Republic

Medium risk. 8 critical or high findings in GDPR outside view, Security headers and 2 other checks.

Security score

52/100

Risk levelMedium

0–100, higher is better. How it is calculated

Fakultní nemocnice Královské Vinohrady is a prominent university hospital in the Czech Republic focused on delivering high-quality patient care and medical education. The website provides comprehensive information for patients, visitors, and healthcare professionals, including services such as COVID-19 vaccination, palliative care, and ethical counseling. The hospital is accredited and demonstrates compliance with GDPR regulations, including a cookie consent mechanism. Technically, the website uses legacy jQuery and Google Analytics for tracking, with basic mobile optimization and accessibility features. Security posture is moderate with room for improvement in security headers and updated libraries. The absence of WHOIS data reduces domain trustworthiness, but the website content and branding strongly indicate a legitimate healthcare institution. Overall, the site is professional and user-friendly, serving a large healthcare audience effectively.

Scanned

NIS2 and GDPR posture

GDPR outside view
40/ 100 · High
Checks completed
7of 7

NIS2 Art. 21(2)

  1. (a) Risk analysis and security policies: Not visible from outside
  2. (b) Incident handling: One indicator
  3. (c) Business continuity, backups and crisis management: Not visible from outside
  4. (d) Supply chain security: Not visible from outside
  5. (e) Secure acquisition, development and maintenance, including vulnerability handling: Partly checked
  6. (f) Assessing the effectiveness of security measures: Not visible from outside
  7. (g) Cyber hygiene and security training: Not visible from outside
  8. (h) Cryptography and encryption: Partly checked
  9. (i) HR security, access control and asset management: One indicator
  10. (j) Multi-factor authentication and secured communications: Not visible from outside

This scan rated NIS2 with an earlier keyword method that is no longer shown; rescan for the per-article view. Risk management, continuity, supply chain, training, MFA, management oversight (Art. 20) and incident reporting (Art. 23) need internal evidence, and Guard cannot tell whether NIS2 applies to this organisation.

GDPR is indicative only, based on publicly visible signals: Articles 7, 12, 13 and 32 of Regulation (EU) 2016/679 and Article 5(3) of the ePrivacy Directive. Not a certification or legal assessment.

Priority findings

8 findings rated critical or high. Fix these first.

  1. GDPR outside view

    These are the privacy signals visitors and data protection authorities look for under GDPR.

    • Critical

      EU business without adequate privacy measures

      EU businesses are subject to strict GDPR requirements

      What to do: Implement comprehensive GDPR compliance including privacy policy, cookie consent, and data protection measures

    • High

      No Privacy Policy found

      GDPR requires a clear and accessible privacy policy

      What to do: Add a comprehensive privacy policy page and link to it prominently

  2. Security headers

    Security headers are instructions your web server sends to every visitor’s browser. Missing ones leave visitors more exposed to attacks such as clickjacking and injected scripts.

    • High

      Missing Strict-Transport-Security header

      Forces HTTPS connections

      What to do: Add "Strict-Transport-Security: max-age=31536000; includeSubDomains; preload"

      • CWE-319
      • OWASP A04:2025
      • ASVS V3.4.1
    • High

      Missing X-Frame-Options header

      Prevents clickjacking attacks

      What to do: Add "X-Frame-Options: DENY" or "X-Frame-Options: SAMEORIGIN"

    • High

      Missing Content-Security-Policy header

      Controls resources the browser is allowed to load

      What to do: Implement a Content-Security-Policy appropriate for your application

      • ASVS V3.4.3
      • OWASP Secure Headers: OWASP Secure Headers Project recommends Content-Security-Policy: default-src 'self'; form-action 'self'; base-uri 'self'; object-src 'none';…

Need hands-on remediation? Email guard@offseq.com

Keep watching fnkv.cz

This scan found 22 issues across 6 checks. Monitoring re-runs those checks daily, emails you when something material changes and records each fix, so you can show progress.

Daily monitoring

Recommended

€25per month

  • TLS certificates and expiry
  • DNS records
  • SPF, DKIM and DMARC
  • Security headers
  • GDPR and NIS2 posture
  • Exposed services
  • Third-party trackers
  • Security score drift

Email alerts on material changes and an exportable JSON history of every change.

Billed monthly to your card. Cancel anytime. See sample alerts.

Full report

€39.90one-time

  • The complete analysis as a PDF you can cite
  • Email delivery with an unlock code
  • Lifetime access to this report

Prices incl. 21% VAT. Secure checkout by Mollie; sold by SEQ SIA, Latvia.

Results by check

Each check with its score, findings and the evidence it collected.

How this score is calculated

The security score runs 0–100, higher is better. It is the plain average of the security checks that completed in this scan, each counted equally. A check that could not run is left out: it counts neither as a pass nor as a fail.

Counted in this score

SSL/TLS
67
Security headers
20
Email security
80
DNS health
85
Network security
20
GDPR outside view
40
Average
52

Not counted

  • NIS2 outside view: Re-weights evidence from the TLS, email, DNS, network and hygiene checks, so counting it would count that evidence twice. Shown on its own.
  • OffSeq Observations: An AI reading of the site, useful context but not reproducible evidence. Shown on its own.

Findings that cap the score at 49

Each of these is serious on its own, so while any is present the site cannot rate better than high risk, however good the other checks are.

  • The certificate is not trusted by browsers
  • The website is not served over HTTPS
  • A database, remote desktop, file-sharing or Telnet service is reachable from the internet
  • The page loads a script from a compromised source
  • The domain registration has expired
  • SPF authorises every server to send mail as the domain

Partial scans

When the site blocks Guard or most checks cannot run, the score covers only the checks that ran (usually DNS and email), is capped at 75 and is shown as partial, without a risk level.

Risk levels

  • Critical0–25
  • High26–49
  • Medium50–75
  • Low76–100

Technical appendix

Business context, site observations and technical notes gathered during the scan, and the standards behind each reference.

Business context

Business profile

The hospital holds a leading position in the Czech healthcare sector as a university-affiliated institution. Its business model centers on providing specialized medical services, education, and public health initiatives. The website reflects a well-structured information architecture targeting patients and medical staff. Partnerships include online appointment systems and sign language interpretation services. The hospital's accreditation and public quality reports enhance its competitive advantage. Growth indicators include active public health campaigns and participation in organ donation projects. The absence of visible terms of service or detailed business registration data online suggests an opportunity to enhance transparency.

Security posture

The website demonstrates a moderate security maturity level with implementation of cookie consent and GDPR compliance. However, the use of an outdated jQuery version presents potential vulnerabilities. No explicit security headers such as Content Security Policy or HSTS were detected, which could expose the site to common web attacks. The lack of published security policies or incident response contacts indicates limited transparency in security governance. No vulnerability disclosure or security.txt files were found, reducing the ability for external security researchers to report issues responsibly. Overall, while no critical vulnerabilities were observed, improvements in security best practices and transparency are recommended to strengthen the hospital's security posture.

Recommendations

  1. Update all JavaScript libraries, especially jQuery, to current secure versions to mitigate known vulnerabilities.
  2. Implement and enforce security headers including Content Security Policy, HSTS, X-Frame-Options, and X-Content-Type-Options.
  3. Publish clear security policies and incident response contacts on the website to improve transparency and readiness.
  4. Add a vulnerability disclosure policy and security.txt file to facilitate responsible reporting of security issues.
  5. Verify and publish accurate WHOIS domain registration data to enhance domain trust and legitimacy.
Site observations

Automated reading of the public site. Ratings are indicative.

Business

Company
Fakultní nemocnice Královské Vinohrady
Description
Fakultní nemocnice Královské Vinohrady is a university hospital aiming to provide exemplary patient care and comprehensive health services.
Key services
Patient care, Vaccination (COVID-19), Palliative care, Ethical counseling, Health promotion programs, Organ donation participation, Medical education
Content quality
good
Branding
consistent

Technology

Stack
jQuery 1.7.1, Google Analytics (ga.js), CookieConsent script
Performance
moderate
Mobile
basic
Accessibility
basic
SEO
basic

Security

Observed score
65/100
Good practices seen
  • Cookie consent mechanism implemented
  • No exposed sensitive data in HTML

Analytics and tracking

Services
Google Analytics
Tracking level
moderate
Privacy practices
good

Advertising

Transparency
basic

Site quality

Design
good
User experience
good
Content relevance
good
Navigation
good
Professionalism
good
Trustworthiness
high

Key observations

  1. Website is fully accessible with rich content in Czech language.
  2. No WHOIS data available, which is unusual for a public institution domain.
  3. Cookie consent and GDPR compliance are implemented properly.
  4. No explicit security headers detected in the HTML content.
  5. Uses outdated jQuery version which may pose security risks.
  6. No visible email addresses found in the HTML content.
  7. Phone contact is clearly displayed in header.
  8. No social media links detected in the provided HTML.
  9. Multiple internal links to hospital services and information pages.
  10. No terms of service page detected.
Technical notes

Notes

The website uses legacy jQuery 1.7.1 and Google Analytics for tracking user behavior. It employs a cookie consent mechanism compliant with GDPR. The HTML structure is valid and includes meta tags for SEO and accessibility, though mobile optimization is basic. No modern CMS or frameworks were detected. Hosting provider and SSL configuration details are not available from the provided data. Performance appears moderate with no major blocking scripts. The site could benefit from modernization of its tech stack and improved mobile responsiveness to enhance user experience and security.
Standards and sources

Reference chips under each finding point to the standard, regulation or specification the finding relates to. They are taken from the official datasets below and mapped conservatively: a finding with no defensible link shows none. NIS2 and GDPR references mark where a finding is relevant evidence, not a compliance verdict. Implementing Regulation (EU) 2024/2690 binds digital infrastructure and digital service providers; for other entities it is the most detailed public reading of the Article 21 measures. WCAG, EN 301 549, European Accessibility Act and Web Accessibility Directive references name the requirement an automated accessibility rule relates to; they are not a conformance verdict.

Retrieved 2026-10-25

Reviews of this site

Share your experience with fnkv.cz. Every review is verified by email and published after moderation.

Overall rating
Select a rating
4000 characters remaining

We’ll email you to confirm your review and keep your details private.

Community rating

No published reviews yet. Be the first to review fnkv.cz.

Feedback on this report

Rate this report, add an optional comment, and tell us if you want a security specialist to follow up.

Overall report quality
Select a rating
2000 characters remaining

We only use your feedback to improve Guard reports. Contact details are never shared.